Pump and Signal Combiner Guide: (2+1), (6+1), (18+1) and 7×1

Pump fibers merging into one double clad fiber with the signal core running through

A fiber laser has one junction where several pump fibers meet a single double-clad fiber, and that junction is where most of the thermal risk in the build ends up. The part that makes the junction is the pump combiner. It carries pump light from a bundle of multimode fibers into the inner cladding, and it carries the signal through the same package without disturbing the core.

At a glance
  • 93% pump coupling on the 800 W PM combiner leaves 56 W of pump light inside the package, and that light becomes heat.
  • 0.5 dB of signal loss at 3 kW is roughly 326 W of heat in a component that fits in two fingers.
  • 1.35:1 is the taper a six-port 220 µm bundle needs to enter a 400 µm cladding, and it lifts the pump NA from 0.22 to about 0.30.

What the part does inside the cavity

Pump diodes deliver light into multimode fiber. The gain fiber is double clad: a small doped core for the signal, surrounded by a much larger inner cladding that carries the pump, surrounded again by a low-index outer coating. The combiner brings the pump fibers together, tapers the bundle down, and splices it to the inner cladding. Signal light enters and leaves through the core, which runs straight through the package.

That gives the part two jobs with opposite demands. The pump path wants as much multimode light as possible to enter the cladding while staying inside the cladding’s acceptance angle. The signal path wants a core that matches the gain fiber, with a splice that costs almost nothing. A design that does well on one can hurt the other, which is why the port count, the pump fiber diameter and the signal fiber are chosen together.

Diagram of a pump combiner: six pump fibers taper into the inner cladding of a double-clad gain fiber while the signal core runs straight through
Pump light enters from the left through the multimode fibers and is tapered into the inner cladding. The signal core passes through the same package and continues into the gain fiber on the right. The taper is where brightness is preserved or lost.

Where the pump light actually goes

Pump coupling efficiency is the fraction of launched pump power that appears in the cladding at the output. It is quoted as a minimum on the datasheet, and the useful question is where it was measured. A figure taken at low power on a single port says little about a part that will run at 800 W per port with six ports live.

The limiting piece is the taper. Six fibers of 220 µm laid into a bundle occupy an effective diameter of about 539 µm, so the taper has to reduce the bundle to the 400 µm cladding of a 20/400 gain fiber, a ratio of roughly 1.35:1. Tapering preserves etendue, so the numerical aperture rises by the same factor: 0.22 in becomes about 0.30 out. The inner cladding of a 20/400 LMA fiber is specified around NA 0.46, so there is headroom, but the margin shrinks as ports are added or pump fibers get larger.

Ask for this

Taper ratio does not usually appear on a combiner datasheet. Ask for the pump fiber type and the output fiber type instead, and the ratio follows from the geometry. If a supplier will not name the pump fiber, the coupling figure cannot be checked against anything.

The (6+1)x1 Pump Combiner – 800W lists 800 W on the pump path and a 1064 nm signal path. The PM version of the same configuration is published with a minimum pump efficiency of 93% and a maximum signal insertion loss of 0.5 dB. Those two lines are what a link budget can be built on: 800 W of pump at 93% leaves 744 W in the cladding and 56 W to be managed as heat inside the package.

Signal loss is a heat source

Insertion loss is written in decibels, which hides how much power it removes. The conversion is a straight calculation: dissipated power equals the input power multiplied by one minus ten to the power of minus loss divided by ten. At a few hundred watts the result is small enough to ignore. At a few kilowatts it decides the cooling design.

Insertion loss1 kW signal2 kW signal3 kW signal
0.1 dB23 W46 W68 W
0.2 dB45 W90 W135 W
0.3 dB67 W134 W200 W
0.5 dB109 W217 W326 W

Power removed from the signal path at common insertion loss values

Those watts do not leave through the output fiber. They are absorbed close to the splice and the taper, in the glass, in the coating and in the package. A combiner specified at 0.5 dB for a 3 kW system is therefore also a 326 W heater, and it has to be mounted as one.

Every tenth of a decibel in the signal path is about 70 W of heat at 3 kW. That is the part of the budget most often left out of the quote.

This is also why an insertion loss field that reads “application dependent” is worth pushing back on. It means the value will be set at order, so ask for a worst-case number at the rated power, with the signal fiber and splice configuration you intend to use, and ask whether it was measured after the package was assembled.

Where the heat goes

Heat leaves a fused combiner by conduction into its housing, and from the housing into whatever it is mounted on. The temperature rise is the dissipated power multiplied by the thermal resistance from the hot spot to the mounting surface. A low-loss fused package in a metal housing typically sits somewhere between 0.2 and 0.5 K/W, which is a number a supplier can state and a test can confirm.

At 56 W of pump heat and 0.4 K/W, the package runs about 22 K above the baseplate. Add the signal contribution at high power and the internal temperature climbs further, and the low-index polymer that keeps the pump inside the cladding is the first material to care. Its long-term limit is well below the melting point of the glass, and it degrades quietly: loss rises, heat rises, and the part keeps working until it does not.

Bar chart of heat dissipated in a pump combiner at 0.1, 0.2, 0.3 and 0.5 dB insertion loss for 1, 2 and 3 kW signals
Heat left inside the part follows signal power as well as insertion loss. The same 0.5 dB that costs 109 W at 1 kW costs 326 W at 3 kW.
Test at rated power

A combiner that passes inspection at 10% power has not been tested at the taper. Run the acceptance test at rated pump power with the cooling the field unit will use, hold it until the housing temperature stabilizes, and record the hot spot with a thermal camera. Two builds that both pass a low-power test can differ by 30 K in service.

Port count follows the pump diodes

The number of pump ports is not a preference. It comes from how much pump power the design needs and how much each diode can deliver. A 1080 nm oscillator running at about 65% optical-to-optical efficiency needs roughly 1.5 kW of pump for 1 kW of signal. Dividing that by 100 W per pump fiber gives 15 ports, and by 250 W gives six. The combiner also carries a total pump rating that is separate from the port count: our 6+1 part is listed at 800 W, so a 1.5 kW budget is usually split between a forward and a backward combiner placed at each end of the gain fiber.

That arithmetic explains the shape of a combiner catalog. Small 2+1 parts serve low-power amplifiers, seed stages and 1550 nm work. A 6+1 part at 800 W serves kilowatt oscillators built on high-power pump modules. An 18+1 part at 300 W suits designs that use many lower-power diodes, where the loss in brightness per port is traded for redundancy and thermal spread.

ConfigurationPump wavelengthPump powerSignal fiberPolarization
2+1, miniature976 nm30 WSet at orderNon-PM
2+1800 to 1000 nm800 W per port14/250 LMANon-PM
6+1976 nm800 WSet at orderNon-PM
6+1, PM976 nm800 W20/400 PMPM, PER 20 dB min
18+1976 nm300 WSet at orderNon-PM
7×1793 nm50 W200/220 multimodeMultimode
4+1 with HR-FBG976 nm2000 W outputSet at orderNon-PM

Published configurations in the Optishine combiner range. Fiber type and package are set at order.

The 793 nm entry is the odd one, and it is there for a reason. Thulium-doped fibers absorb around 790 nm, so a 2 µm source needs a combiner built for that band, with pump fibers that match the diodes used there. Wavelength is the first row to check when a design moves away from ytterbium.

One more pump-side effect belongs in this section. Pump diode emission drifts with temperature by roughly 0.3 nm per °C, and the ytterbium absorption peak near 976 nm is only a few nanometers wide. A 20 °C swing in a water-cooled stack is enough to move the pump off the peak. The combiner does not cause this, but the resulting unabsorbed pump light lands in the cladding and eventually in the package, so the thermal design has to allow for it.

Matching the signal fiber and the polarization

The signal fiber inside the combiner should be the same fiber as the gain fiber, or close enough that the splice adds a negligible loss. Our parts are published with 20/130 for a 30 W PM build, 20/400 for an 800 W PM build and 14/250 for an 800 W-per-port non-PM part. The core size sets the signal path; the cladding sets how much pump light can be carried with the brightness the design can use. Those two sizes move together as power rises.

When the signal fiber does not match, you get a splice you did not plan for, and a splice at multi-kilowatt power is a second heat source with its own failure mode. Ask what the combiner is built on before comparing prices, because two quotes with the same port count can be built on different fiber and the cheaper one may need an extra splice.

Polarization adds a requirement that the non-PM parts do not have. A polarization-maintaining combiner has to keep the slow axis aligned through the package, and the published figure is usually a minimum polarization extinction ratio, 20 dB on our PM parts. That corresponds to about 1% of the power in the wrong axis. The number that matters in practice is the PER of the assembled chain, including every splice between the seed, the combiner and the gain fiber, so the combiner’s own figure is a ceiling rather than a result.

The product pages also list signal direction as forward or backward. A backward-pumped amplifier has the pump entering from the output end, so the combiner is built and tested in that orientation. Ordering the wrong one is not a wiring problem you can fix in assembly.

Failures that appear after a few hundred hours

Combiner failures in the field tend to share one signature: the part works at first, then loss rises slowly, then the package runs hot, then something in the chain shuts down or burns. The table below maps the visible symptom back to the mechanism worth checking first.

What you seeLikely mechanismWhat to check
Housing temperature climbs over weeksCoating degradation at the taper after sustained operation above its limitThermal image at rated power, compare with the acceptance record; check baseplate flatness and mounting torque
Pump power at the output falls on one port onlyDamage or contamination at that pump connector, or a failed splice on that fiberMeasure each port separately before and after cleaning; inspect the connector end face
Signal loss rises with power but not at low powerAbsorption at a splice or in the package, often with cladding light strippingCut-back measurement at two power levels; look for light escaping the package
PER degrades after a repairSlow axis misaligned during re-splicing of the PM pathMeasure PER through the assembled chain, not just the combiner

Common combiner failure mechanisms and where to look

None of these are caught by a low-power pass test. The acceptance record is what makes a service claim possible later, so keep the thermal image and the port-by-port readings with the serial number.

Pre-spliced or loose delivery fibre

A combiner with a 20/460 output can leave the factory in two forms: as a complete assembly with the delivery fibre already spliced and tested, or with the output fibre loose so the customer splices it on site. The second is cheaper on the invoice and usually more expensive in the field.

Two reasons. First, the splice on a large-cladding output is where the unabsorbed pump light and the signal meet, and the tolerance for offset is measured in microns. Second, any loss at that joint turns into heat inside a few millimetres of fibre, where nothing can cool it: at 3 kW, 1% is 30 W in a spot smaller than a grain of rice.

Pre-spliced assemblyLoose fibre, spliced in-house
Splice measured before shippingYes, recorded per unitNo
Who owns the failureThe supplierThe customer
Field equipment neededNoneA splicer rated for the cladding, plus a test source
Cost on the invoiceHigherLower

We ship high-power combiners pre-spliced, with the splice loss recorded, and we say so when a customer asks for a loose fibre to save cost — the decision is theirs once they know what the joint will be asked to carry.

What to send with the RFQ

A combiner quote is firm or it is not. It is firm when the supplier knows the pump source, the signal fiber, the mounting and the test conditions. The list below is the one we ask for, and a quote that comes back without these details is worth a second round of questions.

  • Port configuration and how many ports will run at the same time
  • Pump wavelength, pump power per port and the diode type or module
  • Pump fiber core and cladding diameter, and numerical aperture
  • Signal wavelength, signal power and the gain fiber type
  • Polarization requirement, with a target PER for the assembled chain
  • Forward or backward pump direction, and where the combiner sits in the layout
  • Cooling method, baseplate temperature and mounting surface
  • Acceptance test and the record you expect with each unit

With those eight answers a supplier can name the fiber, the package and the cooling, and can commit to numbers that survive a test. Without them, the only number that can be quoted honestly is the port count.

Which configuration: (2+1), (6+1), (18+1) or 7×1

The port count is set by the pump diodes, not by preference. Once the pump power and the signal path are fixed, the configuration usually falls out of two numbers: how much pump power is needed, and whether the signal runs forward or backward through the combiner.

ConfigurationPump / signalSignal ILPump efficiencyPower handlingTypical use
(2+1)×1800–1000 nm / 1030–1080 nm≤0.3 dB≥98%800 W per portCompact amplifier stages
(6+1)×1typ. 915 nm / typ. 1064 nm≤0.3 dB≥98%1000 W per port1 µm amplifier workhorse
(6+1)×1 PM976 nm / 1030 nm≤0.5 dB≥93%PER ≥20 dBPM seed path, backward pumping
(18+1)×1976 nm / 1064 nmper designper design300 W outputIndustrial high-power sources
7×1793 nm (thulium)per design≥92%50 W per port2 µm pumping
(6+1)×1 MPC940 nm / 1550 nm≤0.8 dB≥93%3 × 20 WEr-doped stages, sensing

Two rules of thumb from the table. First, signal insertion loss is the price you pay for adding pump ports: the (2+1) and (6+1) sit at 0.3 dB, the PM and 1550 nm versions at 0.5–0.8 dB. Second, PM is not an upgrade you add later — a non-PM combiner in a polarization-maintaining chain sets the extinction ratio for every component after it.

Optishine combiner families

These are the configurations we publish today. The figures below are the ones on the product pages; the exact fiber, package and cooling are fixed per order, so send the list above and the configuration gets confirmed against your build.

Further configurations in the range include an 18+1 part at 300 W for designs that use many lower-power diodes, a 30 W miniature 2+1 for amplifiers and seed stages, and a 7×1 part at 793 nm for thulium pumping. All of them are in the product catalogue with their published rows.

For the amplifier side of the same build – how noise figure, gain flatness and output power are specified – see Common questions

What is the difference between a pump combiner and a signal combiner?

A pump combiner merges several pump diodes into one fiber that then feeds the gain fiber; the signal passes through the same package but is not combined with anything. So a “pump and signal combiner” is one package carrying two jobs: N pump ports combined, plus one signal path in and out. The (N+1) notation describes exactly that — N pump ports plus one signal port.

Should I choose 6+1 or 7×1?

They describe different jobs. (6+1)×1 combines six pump ports around one signal fiber, and is the usual choice for 1 µm amplifiers at 915 or 976 nm. A 7×1 with no signal port is a pure pump combiner, used where the signal is handled separately — for example thulium pumping at 793 nm, where our 7×1 handles 50 W per port at 92% efficiency.

Does a higher port count always mean more power?

No. Power handling per port is limited by the diode and the fiber, and the package has to dissipate the pump light that is not coupled. An (18+1) at 300 W output can be the right part while a (6+1) at 1000 W per port is over-specified for a small stage. Match the configuration to the pump budget, not to the largest number in the catalogue.

References

If a combiner is already in the design and the numbers do not line up, send the configuration with the pump source, signal fiber and cooling details. The arithmetic above takes a few minutes once those are known.